UL Cables.

UL Approved Styles

UL 1007

Internal wiring of appliances. Tags may indicate the following: 600 V Peak - For Electronic Use Only.

32 AWG - 16 AWG

80 deg C, 300 Vac, Horizontal flame. Optional - 60 deg C or 80 deg C Oil.

Conductor Type: Annealed Bare Copper(ABC) / Annealed Tinned Copper (ATC)(ATC)

Conductor Construction: Solid or Stranded

Insulation: PVC

UL 758, UL 1551, UL 2556

UL 1028

Internal wiring. Tags may indicate the following: 2500 Volts Peak - For Electronic Use Only.

22 AWG - 6 AWG

105, 600 Vac, Horizontal flame. Optional - 60 deg or 80℃ Oil

  • Conductor Type: Annealed Bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: Solid or Stranded
  • Insulation: PVC

UL 758, UL 1551, UL 2556

UL 1062

Internal wiring of appliances or electronic equipment.

20 AWG-18 AWG

60, 300 Vac, Horizontal flame

  • Conductor Type: Annealed Bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: Solid or Stranded
  • Insulation: PVC
  • Shield: Optional
  • Jacket: PVC

UL 758, UL 1551, UL 2556

UL 10107

Internal wiring of appliances or electronic equipment.

30 AWG - 750 kcmil

80℃, 90, or 105 , 600 Vac, FT2 flame

  • Conductor Type: Annealed Bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: Solid or Stranded
  • Insulation: PVC
  • Shield: Optional
  • Jacket: PVC

UL 758, UL 1551, UL 2556

UL 10572

External wiring

Minimum 30 AWG

105 , 1000 Vac, Horizontal flame, Cable flame

  • Conductor Type: Annealed Bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: Solid or Stranded round
  • Insulation: Single conductor, Labeled or complies with Manufacturer's AWM Procedure
  • Shield : Optional
  • Covering : Optional 
  • Jacket : PVC

UL 758, UL 1551, UL 2556

UL 11113

Appliance Wiring Material

Minimum 32 AWG - 10 AWG min

80 , 600 Vac

  • Conductor Type: Annealed Bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: Solid or Stranded round
  • Insulation: PVC

UL 758, UL 1551, UL 2556

UL 1015

Internal Wiring of Appliances. Tags may also indicate the following: 2,500 V peak - for electronic use only.

30 AWG - 2000 kcmil

80, 90, or 105 deg C, 600 Vac or 750 Vdc, Horizontal flame. Optional - 60 or 80 deg C Oil

  • Conductor Type: Annealed Bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: Solid or Stranded round
  • Insulation: PVC

UL 758, UL 1551, UL 2556

UL 1032

Internal Wiring of Appliances. Tags may also indicate the following: 3500 V peak - for electronic use only.

30 AWG - 2000 kcmil

90 , 1000 Vac and/or 1200 Vdc, Horizontal flame. Optional - 60 or 80 deg C Oil

  • Conductor Type: Annealed Bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: Solid or Stranded
  • Insulation: PVC
  • Covering: Optional, Extruded PVC
  • Shield: Optional
  • Jacket: Optional, Extruded PVC

UL 758, UL 1551, UL 2556

UL 1569

Internal wiring of appliances or electronic equipment was not subjected to movement or mechanical damage. The tag may also indicate the following,600 Volts Peak for Electronic Use Only.

30 AWG - 2 AWG

80, 90 or 105 deg C, 300 Vac, Horizontal flame

  • Conductor Type: Annealed Bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: Solid or Stranded
  • Insulation: PVC
  • Covering: Optional, Extruded PVC

UL 758, UL 1551, UL 2556

UL 10557

External Interconnection or Internal Wiring

0 AWG Minimum

80, 90, 105 deg C; 600, 1000 Vac, Horizontal Flame, Cable Flame

  • Conductor Type : Annealed Bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: Solid or Stranded
  • Insulation: Labeled or complying with Manufacturer's AWM Procedure
  • Shield: Optional
  • Jacket: PVC

UL 758, UL 1551, UL 2556

UL 10692

Internal wiring

32 AWG Minimum

105 deg C, 1000 Vac, Horizontal flame.

  • Conductor Type: Annealed Bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: Solid or Stranded
  • Insulation: Labeled or complying with the manufacturer's AWM procedure. 
  • Covering: Optional
  • Shield: Optional
  • Jacket: PVCa

UL 758, UL 1551, UL 2556

UL 2127

Internal wiring of appliances or electronic equipment

18 AWG - 9 AWG 

105 deg C, 600 Vac, Horizontal flame

  • Conductor Type:  Annealed Bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: Solid or Stranded round
  • Insulation: PVC 
  • Shield: Optional
  • Jacket: PVC

UL 758, UL 1551, UL 2556

UL 2129

Internal wiring

18 AWG - 9 AWG 

60, 80, 90, or 105 deg C; 600 or 1000 Vac, Horizontal flame

  • Conductor Type: Annealed Bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: Solid or Stranded 
  • Insulation: PVC 
  • Shield: Optional
  • Jacket: PVC

UL 758, UL 1551, UL 2556

UL 2516

External interconnects

40 AWG Minimum 

105 deg C, 600 Vac, Cable flame

  • Conductor Type: Annealed Bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: Solid or Stranded 
  • Insulation: PVC 
  • Shield: Optional
  • Jacket: PVC

UL 758, UL 1551, UL 2556

UL 2587

External interconnection or Internal wiring

40 AWG Minimum 

90 deg C, 600 Vac, Cable flame

  • Conductor Type: Annealed Bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: Solid or Stranded 
  • Insulation: Labeled or complying with Manufacturer's ConductorsAWM Procedure 
  • Shield: Optional
  • Covering: Optional, extruded PVC
  • Jacket: PVC

UL 758, UL 1551, UL 2556

UL 2661

External interconnection of electronic equipment

40 AWG - 6 AWG    

80, 90 or 105 deg C, 300 Vac, Cable Flame

  • Conductor Type: Annealed Bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: Solid or Stranded 
  • Insulation: Labeled or complying with Manufacturer's ConductorsAWM Procedure 
  • Shield: Optional
  • Covering: Optional
  • Jacket: PVC

UL 758, UL 1551, UL 2556

UL 2835

Use No. 1A: Internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors.; Use No. 1B: CABLES - using 30 mils or greater jacket thickness only: External interconnection or internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors.; Use No. 2A: Internal wiring in Class 2 circuits of electronic equipment where not routed along walls, floors, or other abuse areas.; Use No. 2B: CABLES - using 30 mils or greater jacket thickness only: External interconnection or internal wiring in Class 2 circuits

40 AWG Minimum    

60 deg C, 30 Vac, Cable flame for Use No. 1B and 2B, Horizontal flame for Use No. 1A and 2A

  • Conductor Type: Annealed Bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: Solid or Stranded 
  • Insulation: Material not specified for Use No. 1A or 1B. Labeled or complies with manufacturer's Procedure for Use No. 2A or 2B 
  • Shield: Optional
  • Covering: OptionalInsulation, Extruded PVC
  • Jacket: PVC

UL 758, UL 1551, UL 2556

UL 20886

External interconnection or internal wiring of electronic equipment

40 AWG Minimum    

80, 90, 105 deg C, 1000 Vac, 1200 Vdc, Cable flame

  • Conductor Type: Annealed Bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: Solid or Stranded round
  • Insulation: Labeled or complying with Manufacturer's AWM Procedure
  • Shield: Optional
  • Covering: Optional
  • Jacket: PVC

UL 758, UL 1551, UL 2556

UL 2128

Internal wiring

28 AWG - 9 AWG    

105 deg C, 600 Vac, Horizontal flame

  • Conductor Type:  Annealed Bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: Solid or Stranded round
  • Insulation: PVC
  • Shield: Optional
  • Jacket: PVC

UL 758, UL 1551, UL 2556

UL 2464

Internal wiring or external interconnection of electronic equipment

Any size

80 deg C, 300 Vac, Cable flame

  • Conductor Type: Annealed bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: Solid or stranded
  • Insulation:Labeled or complying with manufacturer's AWM Procedure
  • Covering: Optional
  • Shield: Optional
  • Jacket: PVC
  • Braid: Optional

UL 758, UL 1551, UL 2556

UL 2586

External interconnection or internal wiring

40 AWG Minimum  

105 deg C, 600 or 1000 Vac, Cable flame

  • Conductor Type: Annealed bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: Solid or stranded
  • Insulation: Labeled or complying with manufacturer's AWM Procedure
  • Covering: Optional, extruded PVC
  • Shield: Optional
  • Jacket: PVC

UL 758, UL 1551, UL 2556

UL 2598

Internal wiring or external interconnection of electronic equipment

40 AWG Minimum  

60 deg C, 300 Vac, Cable flame

  • Conductor Type: Annealed bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: solid or stranded
  • Insulation: Labeled or complying with manufacturer's AWM Procedure
  • Covering: Optional 
  • Shield: Optional
  • Jacket: PVC

UL 758, UL 1551, UL 2556

UL 2733

External Interconnection or Internal Wiring

Any size

60 deg C, 300 Vac, Cable Flame

  • Conductor Type: Annealed bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: solid or stranded
  • Insulation: Labeled or complying with Manufacturer's AWM Procedure
  • Shield: Optional
  • Covering: Optional
  • Jacket: PVC

UL 758, UL 1551, UL 2556

UL 20200

External Interconnection or Internal Wiring

Any size

60 deg C, 300 Vac, Cable Flame

  • Conductor Type: Annealed bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: solid or stranded
  • Insulation: Labeled or complying with Manufacturer's AWM Procedure
  • Shield: Optional
  • Covering: Optional
  • Jacket: PVC

UL 758, UL 1551, UL 2556

UL 20940

Internal wiring of electronic equipment and appliances

32 AWG Minimum  

80 deg C, 600, 1000 Vac, Horizontal flame

  • Conductor Type: Annealed bare copper(ABC) / Annealed Tinned Copper (ATC)
  • Conductor Construction: solid or stranded
  • Insulation: Labeled or complying with Manufacturer's AWM Procedure
  • Shield: Optional
  • Covering: Optional
  • Jacket: PVC

UL 758, UL 1551, UL 2556

  • Anti - Termite and Anti - Rodent Properties.
  • UV Resistance Properties (As pre ASTM G 154 & 155, ISO 4892-2 Method A, UL 1581)
  • Acid  , Alkali & Oil Resistance 
  • RoHS & REACH compliance

Additional Properties can be added as per customer requirement*